SourcingAI

Earth leakage relay manufacturers

I have found results from4000+products and1000+suppliers aboutEarth leakage relay

Chongqing Blue Jay Technology Co., Ltdmic-icon
Satisfies 2/2 of your requirements
Mining Earth Leakage Relay

Mining Earth Leakage Relay

US$290.00-300.00
1 Piece(MOQ)
Sample Available
110-240 VAC DC Ground Fault Earth Leakage Relay for Mining Industry

110-240 VAC DC Ground Fault Earth Leakage Relay for Mining Industry

US$290.00-300.00
1 Piece(MOQ)
Sample Available
AC DC Digital Cbct Earth Leakage Relay for Earth Leakage Protection

AC DC Digital Cbct Earth Leakage Relay for Earth Leakage Protection

US$180.00
1 Piece(MOQ)
85-265V AC DC Earth Fault Relay for Oil Gas Cement Steel Plants

85-265V AC DC Earth Fault Relay for Oil Gas Cement Steel Plants

US$160.00-180.00
1 Piece(MOQ)
Sample Available
Earth Leakage Relay for VSD VFD PC System Transformer Motor Control Panel

Earth Leakage Relay for VSD VFD PC System Transformer Motor Control Panel

US$130.00-160.00
1 Piece(MOQ)
Sample Available
Industry 85-265V Multichannel Ground Fault Residual Current Monitoring Earth Leakage Relay

Industry 85-265V Multichannel Ground Fault Residual Current Monitoring Earth Leakage Relay

US$50.00-100.00
1 pieces(MOQ)
AC DC 90-240V 16 Channel Earth Fault Earth Leakage Relay for Tt Tn-S Systems

AC DC 90-240V 16 Channel Earth Fault Earth Leakage Relay for Tt Tn-S Systems

US$90.00-100.00
10 Pieces(MOQ)
Sample Available
1-8 Channel Earth Leakage Detector DIN Rail Residual Current Relay

1-8 Channel Earth Leakage Detector DIN Rail Residual Current Relay

US$470.00-500.00
1 pieces(MOQ)
Elr-CH16 Multi-Channel Earth Leakage Relay for TNC-S Tn-S Tt Systems

Elr-CH16 Multi-Channel Earth Leakage Relay for TNC-S Tn-S Tt Systems

US$150.00-160.00
10 Pieces(MOQ)
Sample Available
3 Phase Asynchronous Induction Earth Fault Overload Phase Temperature Motor Protection Relay

3 Phase Asynchronous Induction Earth Fault Overload Phase Temperature Motor Protection Relay

US$60.00-150.00
1 Piece(MOQ)
Sample Available
45-65Hz RS485 Modbus RTU 8 Channel Earth Leakage Relay with Cbct

45-65Hz RS485 Modbus RTU 8 Channel Earth Leakage Relay with Cbct

US$80.00-100.00
10 Pieces(MOQ)
Sample Available
4 Channel LCD Screen Digital Earth Leakage Relay with CT

4 Channel LCD Screen Digital Earth Leakage Relay with CT

US$70.00-90.00
10 Pieces(MOQ)
Sample Available
Switchgear Earth Fault Arc Flash Detection Relay with 12-Channel Current Input

Switchgear Earth Fault Arc Flash Detection Relay with 12-Channel Current Input

US$1,500.00-3,000.00
1 Piece(MOQ)
Zjj-101b 0-1500V DC Ground Fault Detector Device Monitoring Insulation Resistance Earth Fault Leakage Relay for Ungrounded System Protection

Zjj-101b 0-1500V DC Ground Fault Detector Device Monitoring Insulation Resistance Earth Fault Leakage Relay for Ungrounded System Protection

US$70.00-90.00
5 Pieces(MOQ)
DC Insulation Monitoring Relay for Current Leakage Insulation Resistance

DC Insulation Monitoring Relay for Current Leakage Insulation Resistance

US$1,000.00-3,000.00
1 Piece(MOQ)
Sample Available
Areva Overload Underload Intelligent Relays Motor Relay Single Phase with Leakage Protection

Areva Overload Underload Intelligent Relays Motor Relay Single Phase with Leakage Protection

US$100.00-180.00
1 Piece(MOQ)

Sourcing guidance for Earth Leakage Relay

What are the key technical specifications to consider when selecting an Earth Leakage Relay (ELR)?

When sourcing an ELR, you must prioritize the Sensitivity Range (typically 30mA to 30A) and the Time Delay settings (0s to 10s) to ensure coordination with other protective devices. Ensure the device supports True RMS measurement to prevent nuisance tripping caused by harmonics in industrial environments. Additionally, verify the Auxiliary Supply Voltage (e.g., 110V, 230V, or 415V AC/DC) matches your local power grid requirements.

Which international compliance standards are mandatory for Earth Leakage Relays?

For global trade, the product must adhere to IEC 60947-2 Annex M (for industrial applications) or IEC 60755 (general requirements for residual current-operated protective devices). If exporting to Europe, CE marking and RoHS compliance are essential. For the North American market, look for UL 1053 recognized components to ensure the safety and legality of the installation.

How do I ensure the compatibility between the ELR and the Core Balance Current Transformer (CBCT)?

The ELR and CBCT (Core Balance Current Transformer) must be technically matched. It is highly recommended to purchase them as a calibrated set from the same manufacturer. Check the internal diameter of the CBCT to ensure it can accommodate all phase cables and the neutral wire. A mismatch in the transformation ratio or saturation characteristics can lead to failure in detecting leakage currents or cause false alarms.

What are the typical usage scenarios for industrial-grade Earth Leakage Relays?

ELRs are critical in Mining, Oil & Gas, and Manufacturing plants where high-power motors and heavy machinery operate. They are used for Fire Protection (setting sensitivity at 300mA-500mA) and Personnel Protection (setting sensitivity at 30mA). They are also vital in Data Centers and Telecommunications to protect sensitive equipment from insulation faults while maintaining system uptime through adjustable delay settings.

Cross-Border Procurement & Risk Management for Electrical Components

How can I verify the quality of an Earth Leakage Relay supplier on Made-in-China.com?

Prioritize suppliers with the 'Audited Supplier' badge, which indicates that their premises and business licenses have been verified by third-party agencies like SGS or TÜV Rheinland. Request a Type Test Report from an accredited laboratory to confirm the relay's performance under fault conditions. For large orders, consider a Pre-shipment Inspection (PSI) to verify that the trip sensitivity and time delay functions meet your specific order requirements.

What are the common risks in international shipping for sensitive electronic relays?

Electrical relays are sensitive to Electromagnetic Interference (EMI) and Moisture. Ensure the supplier uses Anti-static packaging and Vacuum-sealed moisture-proof bags. For sea freight, specify the use of Desiccants inside the cartons to prevent corrosion of internal copper contacts. Always clarify the Incoterms (e.g., FOB or CIF); for high-value electrical components, FOB is often preferred by experienced buyers to maintain better control over the logistics provider and insurance.

What strategies should be used when negotiating bulk pricing for ELRs?

Negotiate based on Annual Volume Forecasts rather than a single spot order to secure a 10-20% discount. Ask for a 'Sample Rebate' where the cost of initial samples is deducted from the first bulk order. Additionally, discuss Warranty Extensions; while the standard is 12 months, top-tier suppliers on Made-in-China.com may offer 24 to 36 months for high-volume partnerships, which significantly reduces your long-term operational risk.

How do I ensure transaction security and payment safety?

Utilize Secured Payment services provided by Made-in-China.com to ensure that funds are only released to the supplier after you confirm receipt of the goods. Avoid making full payments upfront; a standard 30% deposit and 70% balance against the Bill of Lading (B/L) is the industry norm. Always verify that the beneficiary bank account name matches the registered company name on the platform to prevent phishing scams.

Related queries