Flame detector
I have found results from10000+products and6000+suppliers aboutFlame detector
ATEX IP66 Explosion-Proof Point-Type Infrared Flame Detector for Oil Refineries
S600-Exir3 High-Sensitivity CE and ATEX Point Type Infrared Flame Detector
Manufacturer of UV/IR Flame Detector IR3 Approvals ATEX Flame Detector
S600 Anti-Corrosion Explosion Proof Point Type Fixed Type IR-UV Flame Detector
Top Rated UV IR2 Flame Detector for Industrial Facilities
PRO UV IR Flame Detector with Triple IR Technology for Shipboard Safety
UV IR Flame Detector Ultraviolet Infrared Fire and Gas Detection Explosion Proof Flame Detector
Explosion-Proof Fast Infrared Flame Detector for Fire Alarm System (D623)
High Performance Explosion Proof Infrared Flame Detector (D623)
UV-IR Composite Flame Detector Explosion-Proof Fixed Flame Alarm Monitor Harsh Environment Use
Industrial Multi-Level Sensitivity Flame Detector IR3 Three-Band Infrared Flame Detector Hart Output (optional)
IP66 UV-IR Composite Flame Detector Explosion-Proof Flame Detector for Oil and Gas Industrial Fire Alarming
Explosion-Proof Double IR Flame Detector with Alarm Multi-Level Sensitivity Infrared Fire Sensor for Chemical Plant
Flame Detector UV Flame Detector Relay Output with Fire Alarm System
Relay Output Exproof Three Band Flame Detector Point Type Infrared Flame Detector
Honeywell C7027A1049 Minipeeper Ultraviolet Flame Detectors C7027A 1049
4-Wire, Non-Addressable Flame Detector with Auto-Reset, Smoke Detector
Best-Selling Photoelectric, 12/24V, Flame Detector with Relay Output
Outdoor Forest Fire Detector UV Flame Detection Alarm Ground Fire Gas Analyzer
Point Type Ultraviolet Flame Detector Fire Gas Detector
Environmentally Friendly Solar Powered Forest Flame Detector UV Flame
Smoke Detector Fire Alarm CO,Gas,Flame Detector Alarm System
Long Detect Distance Fire UV-IR2 Industrial Flame Detector Price
Ex IR Fire Detector/Infrared Flame Detector for Fire Alarm Security System
AS-E302-UV Explosion-Proof Ultraviolet Flame Detector
DC24V Ultraviolet Flame Detector with Relay Output for Fire Alarm Systems
24V Conventional UV Flame Detector Fire Alarm Sensor
UV Flame Detector Asenware Explosion Proof Flame Detector UV IR Flame Detector
Sourcing guidance for Flame Detector
How to choose the right detection technology for different industrial environments?
Selecting the correct sensor type is critical for preventing false alarms. UV (Ultraviolet) detectors are extremely fast but can be triggered by lightning or welding. IR (Infrared) detectors are better at seeing through smoke but may be sensitive to modulated blackbody radiation. For high-risk oil and gas environments, Multi-spectrum IR (Triple IR/IR3) is the gold standard as it offers the longest detection range and the highest immunity to false alarm sources like sunlight or hot machinery.
What are the essential compliance standards and certifications for flame detectors?
Since these are life-safety devices, they must carry international explosion-proof and performance certifications. Ensure the products are ATEX or IECEx certified for hazardous areas (Zone 0, 1, or 2). For functional safety, look for SIL 2 (Safety Integrity Level) rating. In terms of performance, compliance with EN 54-10 or FM 3260 is mandatory to guarantee the device detects specific fuel fires within a defined timeframe and distance.
What technical specifications should be prioritized during the sourcing process?
Buyers should focus on the Field of View (FOV), typically 90° to 120° horizontal, to ensure maximum coverage area. The Response Time is equally vital; high-quality detectors should trigger an alarm in less than 5 seconds. Additionally, verify the Housing Material—for offshore or corrosive environments, Stainless Steel 316L is preferred over aluminum for its superior durability and corrosion resistance.
How to evaluate the integration capabilities of flame detectors with existing systems?
The detector must communicate seamlessly with the Fire Alarm Control Panel (FACP) or DCS. Ensure the device supports multiple output options such as 4-20mA analog signals, Relay outputs (Alarm & Fault), and RS-485 Modbus communication. For modern smart factories, check if the supplier provides HART protocol support, which allows for remote diagnostics and calibration without removing the unit from the field.
Cross-Border Purchasing Considerations for Flame Detectors
What are the primary risks when importing flame detectors across borders?
The biggest risk is regulatory non-compliance at customs. Flame detectors are often classified as 'dual-use' or high-tech safety equipment. Ensure the supplier provides a Certificate of Origin and that the HS Code (typically 8531.10) is correctly declared. Failure to match the physical product markings with the provided test reports (e.g., IP66/IP67 ratings) can lead to shipment seizures or heavy fines.
How can I verify the reliability of a Chinese supplier for high-precision safety equipment?
When sourcing from Made-in-China.com, prioritize Audited Suppliers who have undergone on-site inspections. Request a video factory audit to see their optical calibration darkrooms and testing labs. A reliable manufacturer should be able to provide batch-specific calibration certificates and have a proven track record of exporting to regulated markets like the EU or Middle East.
What strategies should be used for price negotiation and transaction security?
Do not negotiate on price at the expense of sensor quality; instead, negotiate based on Total Cost of Ownership (TCO), including the cost of spare parts and mounting brackets. Use Secured Trading services on Made-in-China.com to ensure payment is only released after the goods pass a third-party pre-shipment inspection (PSI). This is crucial for verifying that the internal sensors are genuine and not lower-grade components.
What are the best practices for international shipping and handling of sensitive optical sensors?
Flame detectors contain sensitive optical lenses and electronic components. Require the supplier to use anti-static vacuum packaging and shock-absorbent foam inserts. For shipping to distant regions, specify sea-worthy wooden crates or reinforced double-wall cartons. Ensure the bill of lading includes 'Fragile' and 'Handle with Care' instructions to prevent misalignment of the internal optical axis during transit.