Product Attributes:
Type: Air-Cooled
Power Source: Electric
Frozen and Chilled
Automatic Grade: Automatic
Application: Ice Cream
Customized: Non-Customized
Cooling Method: Direct Cooling
Certification: CE
Condition: New
Storage Pressure Vessel
Material: Carbon Steel
Storage Medium: Moncombustible/Nontoxic
Low Pressure (0.1MPa≤p<1.6MPa)
Suitable for Car Brands: Ford
Component: Thermostat
Body Material: Aluminium
Cold Style: Air-cooled
Structure: Sealed Type
Cooling Fluid Type: Alcohol
Radiator Type: Direct-flow
Unit Structure: Integral
Selected Voltage: 380V/50HZ
Compressor Number: 2
Noise Level: Low
Application Fields: Food Processing
Rotation Speed: 100-1000rpm
Additional Capabilities: Vacuum
Online Support, video Technical Support
Application Area: Chemical
Heating Method: Electric Heating
Insulation Material: Polyurethane
Main Material: Stainless Steel
Mixing Capacity: 250-499L
Mixing Drum Shape: Disc
Stirring Type: Forced
Warranty: 1 year
Working: Convection Mixer
Pressure: 1.6MPa≤p<10.0MPa
Voltage: 220V
Sealing Method: Totally Enclosed
Cooling Mode: Water-Cooled
Process: Thermal Processing
Application: Gas
Application: Milk
Application: Yogurt
Application: Cheese
Application: Milk Powder
Application: Liquid
Application: Viscous Fluid
Application: Liquefied Gas
Customized: Customized
Cooling Method: Screw
Cooling Method: Air Cooling
Certification: ISO9001
Certification: ISO
Material: Stainless Steel
Storage Medium: Flammable/Toxic
Medium Pressure (1.6MPa≤p<10.0MPa)
Application Area: Daily Chemical
Pressure: 0.1MPa≤p<1.6MPa

Sourcing guidance for Refrigerant Receiver Tank

What are the key technical specifications to consider when selecting a refrigerant receiver tank?

Buyers must prioritize Maximum Working Pressure (MWP) to ensure it exceeds the system's peak operating pressure, especially for high-pressure refrigerants like R410A or R744 (CO2). The internal volume should be sized to hold at least 90% of the total system charge to prevent liquid slugging. Additionally, verify the connection types (solder, flare, or rotalock) and ensure the mounting orientation (horizontal vs. vertical) matches your system design.

Which compliance standards and certifications are mandatory for international trade?

As pressure vessels, receiver tanks must adhere to strict safety codes. For the US market, ASME Section VIII certification is standard. For the EU, CE marking under the Pressure Equipment Directive (PED) 2014/68/EU is mandatory. Additionally, look for UL/cUL listing for electrical and fire safety, and ensure the manufacturer follows ISO 9001 for quality management systems.

How do material choices impact the longevity and performance of the tank?

Most tanks are constructed from carbon steel with a corrosion-resistant powder coating (tested via salt spray for 500+ hours). For marine or highly corrosive environments, stainless steel (304 or 316L) is preferred. Ensure the internal cleanliness meets ASTM B280 standards to prevent compressor contamination from moisture or debris.

What safety features should be integrated into the receiver tank design?

A high-quality receiver tank must include a pressure relief valve (PRV) port or a fusible plug to prevent explosions during over-pressurization. For larger industrial units, integrated sight glasses or liquid level sensors are essential for monitoring the refrigerant charge during operation and maintenance.

Cross-Border Procurement & Risk Management for Pressure Vessels

What are the primary risks when importing refrigerant receiver tanks from overseas?

The biggest risk is non-compliance with local pressure vessel regulations, which can lead to customs seizures or legal liability. Always request Material Test Reports (MTRs) and Hydrostatic Test Certificates before shipment. Another risk is internal oxidation during sea transit; ensure tanks are nitrogen-charged and sealed to prevent moisture ingress.

How can I verify the credibility of a supplier on Made-in-China.com?

Prioritize Audited Suppliers who have undergone third-party verification by agencies like SGS or TÜV Rheinland. Check their export history and specifically look for experience in the HVAC/R industry. Request a video factory audit to inspect their welding robots and leak detection equipment (e.g., Helium leak testing).

What are the best practices for negotiating pricing and MOQs for bulk orders?

Negotiate based on raw material indices (e.g., steel market prices) to ensure fair pricing. For custom sizes, expect a higher MOQ (typically 50-100 units), whereas standard sizes may allow for sample orders of 1-5 units. Ask for tiered pricing where a 20% increase in volume could yield a 5-10% unit cost reduction.

What shipping and logistics precautions should be taken for these components?

Receiver tanks are heavy and prone to denting. Insist on palletized packaging with reinforced corner protectors and shrink-wrapping. Use FOB (Free On Board) terms to maintain control over the freight forwarder and insurance, ensuring the cargo is covered against physical damage and rust during long-haul maritime transport.